Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
PLoS One ; 19(2): e0271711, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38421965

RESUMEN

PURPOSE: Prior to 90Y radioembolization procedure, a pretherapy simulation using 99mTc-MAA is performed. Alternatively, a small dosage of 90Y microspheres could be used. We aimed to assess the accuracy of lung shunt fraction (LSF) estimation in both high activity 90Y posttreatment and pretreatment scans with isotope activity of ~100 MBq, using different imaging techniques. Additionally, we assessed the feasibility of visualising hot and cold hepatic tumours in PET/CT and Bremsstrahlung SPECT/CT images. MATERIALS AND METHODS: Anthropomorphic phantom including liver (with two spherical tumours) and lung inserts was filled with 90Y chloride to simulate an LSF of 9.8%. The total initial activity in the liver was 1451 MBq, including 19.4 MBq in the hot sphere. Nine measurement sessions including PET/CT, SPECT/CT, and planar images were acquired at activities in the whole phantom ranging from 1618 MBq down to 43 MBq. The visibility of the tumours was appraised based on independent observers' scores. Quantitatively, contrast-to-noise ratio (CNR) was calculated for both spheres in all images. RESULTS: LSF estimation. For high activity in the phantom, PET reconstructions slightly underestimated the LSF; absolute difference was <1.5pp (percent point). For activity <100 MBq, the LSF was overestimated. Both SPECT and planar scintigraphy overestimated the LSF for all activities. Lesion visibility. For SPECT/CT, the cold tumour proved too small to be discernible (CNR <0.5) regardless of the 90Y activity in the liver, while hot sphere was visible for activity >200 MBq (CNR>4). For PET/CT, the cold tumour was only visible with the highest 90Y activity (CNR>4), whereas the hot one was seen for activity >100 MBq (CNR>5). CONCLUSIONS: PET/CT may accurately estimate the LSF in a 90Y posttreatment procedure. However, at low activities of about 100 MBq it seems to provide unreliable estimations. PET imaging provided better visualisation of both hot and cold tumours.


Asunto(s)
Neoplasias Hepáticas , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Radioisótopos de Itrio/uso terapéutico , Tomografía de Emisión de Positrones , Tomografía Computarizada de Emisión de Fotón Único , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia
2.
Radiat Prot Dosimetry ; 199(15-16): 1862-1866, 2023 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-37819282

RESUMEN

In the study, the passive multi-layer neutron spectrometer, based on thermoluminescence detectors, was tested in a calibration laboratory with 239Pu-Be and 252Cf isotopic sources. MCNP code was used for the calculation of the response functions for the neutron energy range from 1 meV to 100 MeV. It was also utilised for initial guess spectra calculations. Deconvolution was performed with MAXED and GRAVEL deconvolution codes resulting in the neutron spectra defined at the measuring point in the calibration laboratory.


Asunto(s)
Plutonio , Radiometría , Radiometría/métodos , Californio , Neutrones , Dosis de Radiación
3.
Radiat Prot Dosimetry ; 199(15-16): 1922-1925, 2023 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-37819319

RESUMEN

Extremely important aspects of the boron neutron capture therapy are, first of all, administering to the patient a boron compound that selectively reaches the neoplastic cells, and in the second step, the verification of the irradiation process. This paper focuses on the latter aspect, which is the detailed dosimetry of the processes occurring after the reaction of thermal neutrons with the boron-10 isotope. The results of computer simulations with the use of a new type of human head phantom filled with a polymer dosimetric gel will be presented in this article.


Asunto(s)
Terapia por Captura de Neutrón de Boro , Humanos , Terapia por Captura de Neutrón de Boro/métodos , Radiometría/métodos , Neutrones , Dosificación Radioterapéutica , Fantasmas de Imagen
4.
Radiat Prot Dosimetry ; 199(15-16): 1883-1888, 2023 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-37819336

RESUMEN

In this study, the influence of additional 10B4C polarizing electrodes coating on KW-1 multisignal ionization chamber performance was investigated. Using the FLUKA Monte Carlo code energy deposition, neutron fluence and neutron track-length distributions were simulated. Further calculations allow us to obtain response functions for monoenergetic neutron beams in the energy range from 1 meV to 30 MeV. Results indicate further upgrades that can be adapted for moderator-based gaseous detectors for the neutron beam spectrometry approach.


Asunto(s)
Neutrones , Radiometría , Radiometría/métodos , Simulación por Computador , Método de Montecarlo , Gases
5.
Radiat Prot Dosimetry ; 199(15-16): 1926-1931, 2023 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-37819348

RESUMEN

The aim of the study is to show a method of real-time determination of the dose deposited in a tissue-like medium by α-particles emitted from the 10B(n,α)7Li reaction. The applied research method is to determine the correlation between the measured density of α-particle traces and measured in real time the 478 keV prompt-gamma rays derived from the 10B(n,α)7Li reaction. To achieve this aim, an appropriate construction of an experimental set-up is needed. The experimental set-up built for the purpose of the measurements carried out in the MARIA Reactor at the National Centre for Nuclear Research in Swierk, Poland, is presented. The main challenges related to obtaining optimal conditions for the measurement of the 478 keV gamma photons; the preliminary results of spectrometric measurements and further studies are also discussed.


Asunto(s)
Partículas alfa , Terapia por Captura de Neutrón de Boro , Rayos gamma , Terapia por Captura de Neutrón de Boro/métodos , Radiometría/métodos , Análisis Espectral
6.
J Vis Exp ; (160)2020 06 09.
Artículo en Inglés | MEDLINE | ID: mdl-32597879

RESUMEN

The purpose of the manuscript is to provide a step-by-step protocol for performing immunofluorescence microscopy to study the radiation-induced DNA damage response induced by neutron-gamma mixed-beam used in boron neutron capture therapy (BNCT). Specifically, the proposed methodology is applied for the detection of repair proteins activation which can be visualized as foci using antibodies specific to DNA double-strand breaks (DNA-DSBs). DNA repair foci were assessed by immunofluorescence in colon cancer cells (HCT-116) after irradiation with the neutron-mixed beam. DNA-DSBs are the most genotoxic lesions and are repaired in mammalian cells by two major pathways: non-homologous end-joining pathway (NHEJ) and homologous recombination repair (HRR). The frequencies of foci, immunochemically stained, for commonly used markers in radiobiology like γ-H2AX, 53BP1 are associated with DNA-DSB number and are considered as efficient and sensitive markers for monitoring the induction and repair of DNA-DSBs. It was established that γ-H2AX foci attract repair proteins, leading to a higher concentration of repair factors near a DSB. To monitor DNA damage at the cellular level, immunofluorescence analysis for the presence of DNA-PKcs representative repair protein foci from the NHEJ pathway and Rad52 from the HRR pathway was planned. We have developed and introduced a reliable immunofluorescence staining protocol for the detection of radiation-induced DNA damage response with antibodies specific for repair factors from NHEJ and HRR pathways and observed radiation-induced foci (RIF). The proposed methodology can be used for investigating repair protein that is highly activated in the case of neutron-mixed beam radiation, thereby indicating the dominance of the repair pathway.


Asunto(s)
Neoplasias del Colon/diagnóstico por imagen , Neoplasias del Colon/genética , Daño del ADN/inmunología , Reparación del ADN/inmunología , Técnica del Anticuerpo Fluorescente/métodos , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...